Maintenance, Troubleshooting, Data Analysis and Experimentation in Mass Spectrometry

Mass spectrometry experiment (MS) is a high-throughput experimental method that characterizes molecules by their mass-to-charge ratio. The MS is composed of sample preparation, molecular ionization, detection, and instrumentation analysis processes. MS is beneficial in that it is generally fast, requires a small amount of sample, and provides high accuracy measurements. For these reasons, MS alone or combined with other structural proteomics techniques is widely used for various molecular biology analysis purposes. Examples of the analysis include post-translations modifications in proteins, identification of vibrational components in proteins, and analysis of protein conformation and dynamics. We will focus on MS-coupled methods that provide information about conformation and dynamics of the protein being studied. For a comprehensive review on MS procedures and for a review on various types of MS-coupled methods.The performance of a mass spectrometer will be severely impaired by the lack of a good vacuum in the ion transfer region of the mass analyser.  As the vacuum deteriorates it will become insufficient to maintain biomedical instrumentation in the operating mode. If the foreline pump is not maintained, the oil may become so contaminated that the  optimum pumping is no longer possible.  Initially, gas transport and metabolism ballasting may clean the oil.  If the  oil has become discoloured then it should be changed according to the pump  manufacturers’ maintenance manual.  When rotary pumps are used to pump away conflict resolution, the solvent can  become dissolved in the oil causing an increase in backing line pressure.  Gas  ballasting is a means of purging the oil to remove dissolved contaminants

  • Data independent analysis, representation and acquisition
  • General symptom and chromatographic symptom
  • Temperature and pressure symptom
  • Air leaks, contamination, error message
  • Safty and regulatory certification
  • MSD hardware description
  • Troubleshooting tips and tricks
  • Hyper reaction monitoring

Related Conference of Maintenance, Troubleshooting, Data Analysis and Experimentation in Mass Spectrometry

September 04-06, 2017

5th Global Chemistry Congress

London, UK
September 11-12, 2017

3rd World Chemistry Conference

Dallas, Texas, USA
September 25-27, 2017

5th International Conference on Current Trends in Mass Spectrometry and Chromatography


(10 Plenary Forums - 1Event)
Atlanta, Georgia, USA
September 28-29, 2017
(10 Plenary Forums-1 Event)

2nd International Conference on Clinical Chemistry and Laboratory Medicine

Atlanta, Georgia, USA
October 02-04, 2017

2nd International Conference on Pharmaceutical Chemistry

Barcelona, Spain
(10 Plenary Forums-1Event)
November 02-03, 2017

18th World Conference and Exhibition on Analytical & Bioanalytical Chromatographic Techniques

Atlanta, Georgia, USA
November 15-16, 2017

2nd International Conference on Nuclear Chemistry


(10 Plenary Forums - 1Event)
Las Vegas, Nevada, USA
March 01 - 03, 2018

4th European Organic Chemistry Congress

London, UK
May 17-19, 2018

Global Experts Meeting on Chemistry

Singapore

8th European Chemistry Congress

June 21-23, 2018 Paris, France

Maintenance, Troubleshooting, Data Analysis and Experimentation in Mass Spectrometry Conference Speakers

Recommended Sessions

Related Journals

Are you interested in